DATA
SOURCE:
River Forecast Centers ~5000 stations per day, including ~1500 stations
from the Hydrologic Automated Data System, and Climate Anomaly Data
Base ~several hundred stations per day
RESOLUTION: 0.5 degree x 0.5 degree
DOMAIN: 20N - 60N; 140W - 60W
FORMAT: The format is sequential 32-bit IEEE floating point
created on a big_endian platform (e.g. cray, sun, sgi and hp).
The undefined (missing) value is 9999.
WINDOW: Day 1 analysis is valid for the window from 12Z on day 0
to 12Z on day 1; because of report receipt timing, daily minima are
available 1 day earlier than the maxima and the means.
ANALYSIS SCHEME: Modified Cressman
(1959) scheme (Glahn et al. 1985; Charba et al. 1992). Minimum stations for analysis:
350. If the number of stations is fewer than the minimum, the analysis
is not performed for that day.
QUALITY CONTROL: Climatological
standard deviation check. If a reported value is more than 4 standard
deviations removed from the historical distribution, the value is
omitted from the analysis.
|